Project Description

MX

AIR ASSISTED ATOMIZER
Flat Fan Spray

Flow Rate

Liquid flow rate (l/h): min = 0,50  max = 280
Air flow rate (Nl/min): min = 20,0  max = 685

Liquid flow rate (gph): min = 0,13  max = 73,9
Air flow rate (scfm): min = 0,71 max = 24,3

Materials

AISI 303 s.s., 316L s.s.
Nickel Plated Brass

More materials on request

MX

AIR ASSISTED ATOMIZER
Flat Fan Spray

Flow Rate

Liquid flow rate (l/h): min = 0,50  max = 280
Air flow rate (Nl/min): min = 20,0  max = 685

Liquid flow rate (gph): min = 0,13  max = 73,9
Air flow rate (scfm): min = 0,71 max = 24,3

Materials

AISI 303 s.s., 316L s.s.
Nickel Plated Brass

More materials on request

MX

AIR ASSISTED ATOMIZER
Flat Fan Spray

Flow Rate

Liquid flow rate (l/h): min = 0,50  max = 280
Air flow rate (Nl/min): min = 20,0  max = 685

Liquid flow rate (gph): min = 0,13  max = 73,9
Air flow rate (scfm): min = 0,71 max = 24,3

Materials

AISI 303 s.s., 316L s.s.
Nickel Plated Brass

More materials on request

MX Standard – Type “SA”
Double Air Inlet

MX Standard – Type “SB”
Double Air Inlet

MX Standard – Type “UA”
Single Air Inlet

MX Standard – Type “UB”
Single Air Inlet

      SET-UPS: Pressure principle – Internal mix – Flat spray – 1/4″

FLAT SPRAY
These single orifice set-ups produce a flat fan shaped atomized sprays.More precise details on the spray dimensions are given in the table on the right side of the page.The spray length can reach from 1.800 to 5.200 mm depending upon the set-up type and operating conditions.

COMPLETE CODE
To obtain the complete code for an atomizer it is necessary to use the set-up code you have chosen from the performance table and complete it with the code for body and options as follows.

• Replace the first two letters in the set-up code (SU) with the code for the standard body (MX).
• Add the code for the material you require.
• Add the code for the required options, if any, and the code for thread type.

+39 0383 344611

      SET-UPS: Siphon principle – Internal mix – Flat spray – 1/4″

FLAT SPRAY
These set-ups are designed to work with a liquid fed out of an ambient pressure container, either by liquid siphoning or by gravity head.Therefore the performance tables give the water flow rate for both suction head (blue background) and gravity head (white background).The approximate spray depending upon set-up type and operating conditions are given from the table on the right.

COMPLETE CODE
To obtain the complete code for an atomizer it is necessary to use the set-up code you have chosen from the performance table and complete it with the code for body and options as follows.

• Replace the first two letters in the set-up code (SU) with the code for the standard body (MX).
• Add the code for the material you require.
• Add the code for the required options, if any, and the code for thread type.

+39 0383 344611

      SET-UPS: Pressure principle – External mix – Flat Fan spray – 1/4″

FLAT FAN SPRAY
These set-ups are designed to have two different paths for air and liquid and to eject them through different orifices so that the atomized spray is produced from their impact in the immediate surroundings of the orifices. It is possible therefore to atomize viscous liquids as well as any liquid which might originate a solid build up in the mixing chamber of an ordinary internal mix atomizer.Also, liquid and air pressure can be adjusted independently from each other, which allows for an easy, steady state atomizer regulation.The approximate spray depending upon set-up type and operating conditions are given from the table on the right.

COMPLETE CODE

To obtain the complete code for an atomizer it is necessary to use the set-up code you have chosen from the performance table and complete it with the code for body and options as follows.
• Replace the first two letters in the set-up code (SU) with the code for the air actuated body (MX).
• Add the code for the material you require.
• Add the code for the required options, if any, and the code for thread type.

+39 0383 344611

MX
AIR ASSISTED ATOMIZER- Flat Fan Spray

www.pnr.eu
[email protected]
+39 0383 344611

Materials
AISI 303 s.s.
AISI 316L s.s.
Nickel Plated Brass

SET-UPS: Pressure principle – Internal mix – Flat spray – 1/4″

FLAT SPRAY
These single orifice set-ups produce a flat fan shaped atomized sprays.More precise details on the spray dimensions are given in the table on the right side of the page.The spray length can reach from 1.800 to 5.200 mm depending upon the set-up type and operating conditions.

SET-UPS: Siphon principle – Internal mix – Flat spray – 1/4″

FLAT SPRAY
These set-ups are designed to work with a liquid fed out of an ambient pressure container, either by liquid siphoning or by gravity head.Therefore the performance tables give the water flow rate for both suction head (blue background) and gravity head (white background).The approximate spray depending upon set-up type and operating conditions are given from the table on the right.

SET-UPS: Pressure principle – External mix – Flat Fan spray – 1/4″

FLAT FAN SPRAY
These set-ups are designed to have two different paths for air and liquid and to eject them through different orifices so that the atomized spray is produced from their impact in the immediate surroundings of the orifices. It is possible therefore to atomize viscous liquids as well as any liquid which might originate a solid build up in the mixing chamber of an ordinary internal mix atomizer.Also, liquid and air pressure can be adjusted independently from each other, which allows for an easy, steady state atomizer regulation.The approximate spray depending upon set-up type and operating conditions are given from the table on the right.

PNR Italia 27058 Voghera (PV) Italy – Via Gandini 2
Phone: +39 0383 344611 Fax: +39 0383 212489 E-mail: [email protected]