INDUSTRY
Waste management industry
APPLICATION
Froth Treatment
INDUSTRY

Waste management industry

APPLICATION

Froth Treatment

PROBLEM

Controlling foam build-up in the aeration tank of a biological wastewater treatment plant

SOLUTION

316L stainless steel spiral nozzles

Foam control in biological wastewater treatment plants using spiral nozzle

“Foam build-up in aeration tanks is a recurring challenge in biological wastewater treatment, with direct consequences for process efficiency and operator safety.

The primary challenge on this project was sizing the suppression system within the structural constraints of the installation, while also accounting for the service water quality and the moderately corrosive site conditions.

By selecting spiral nozzles in 316L stainless steel and designing the manifold with an integrated air purge function, we delivered a robust, long-lasting solution with minimal maintenance requirements.”

MATTIA BRUNI
R&D Engineer

The industry

Foam management in biological wastewater treatment

In biological wastewater treatment, aeration tanks are at the core of the purification process. Within them, microorganisms break down organic compounds present in the effluent through a controlled supply of oxygen, delivered by diffusers or blowers.

Intense aeration, surfactants, and suspended biomass all promote the formation of persistent surface foams.

Left uncontrolled, these foams can:

• Overflow the tank, creating slip hazards and contaminating surrounding areas.
• Reduce oxygen transfer efficiency, negatively impacting the biological process.
• Obstruct containment structures and monitoring systems.

PNR Italia, drawing on its expertise in industrial atomization and fluid control, designs custom foam suppression systems that meet the specific requirements of each installation.

The problem

A company specializing in the engineering of industrial water treatment plants needed to address persistent foam formation in the aeration tanks of a biological wastewater treatment facility. Each tank measured 9,000 × 4,500 mm and experienced intense, difficult-to-contain foam production.

The operating conditions presented some specific challenges:

• Risk of nozzle clogging from limescale deposits and splashing of biological sludge.
• Service water quality is potentially aggressive due to the occasional presence of dilute sodium hypochlorite.
• Moderately corrosive environment, owing to the site’s proximity to the sea.
• The impossibility of mounting the distribution line on the handrail requires an alternative arrangement to position the manifold at an adequate height above the water surface.

The goal was to suppress surface foam effectively without interfering with maintenance operations.

The solution

Following a detailed spray coverage analysis of the tank dimensions and operating conditions, we engineered a dedicated solution for each tank, defining the number, position, and spray angle of the nozzles required to ensure uniform coverage of the entire liquid surface.

For each individual tank, the system consists of 11 spiral nozzles in a vertical orientation and 6 spiral nozzles in a horizontal orientation, to ensure lateral coverage.

Spiral nozzles were selected over full-cone alternatives for their superior resistance to clogging: the open-profile geometry maintains water flow even in the presence of limescale deposits or biological sludge contamination.

The material specified is 316L stainless steel, suited to the service conditions of the installation: supply of mains water with the occasional presence of dilute sodium hypochlorite, in a moderately corrosive operating environment.

Water supply is routed through a perimeter distribution pipe, with angled fittings oriented at 120° to optimise flow distribution. The manifold is positioned at an adequate height above the water surface to ensure routine maintenance access without interfering with tank operations.

An air purge system was also included to remove residual water from the nozzles before shutdown — a feature that drastically reduces limescale build-up and extends nozzle service life.

RENDER OF THE AERATION TANK WITH THE FOAM SUPPRESSION SYSTEM IN OPERATION
SECTIONED ISOMETRIC VIEW

Advantages

  • Effective surface foam suppression: the combination of vertical and horizontal sprays ensures complete coverage of the liquid surface in both tanks.

  • Clog resistance: spiral nozzles maintain performance even in the presence of hard water or biological sludge contamination.
  • Reduced maintenance: the automatic air purge removes residual water before shutdown, preventing scale build-up and reducing the frequency of maintenance interventions.

  • Durability in corrosive environments: the 316L stainless steel construction ensures corrosion resistance under demanding conditions, including exposure to dilute sodium hypochlorite.

E

FULL CONE NOZZLES

The E-type full cone nozzle works on the impact principle. It deflects a water stream that impacts onto a spiral-profiled surface, providing the desired spray angle.

Do you have any questions?
Send us a message and we will reply as soon as possible.