INDUSTRY
Chemical
APPLICATION
Washing
INDUSTRY

Chemical industry

APPLICATION

Washing

PROBLEM

Defining the number, position, and spacing of the nozzles needed for complete washing of the demister, while respecting the constraints of the existing supply network

SOLUTION

System with manifolds and full cone nozzles

A dedicated spray coverage analysis defines the number and layout of spiral nozzles for complete, shadow-free washing.

“With a demister, the challenge isn’t washing more; it’s washing well: we studied the nozzle layout jet by jet to guarantee full surface coverage while staying within the flow and pressure limits of the existing line.”

STEFANO BISSACO
Sales Manager

The industry

What a demister is, and why it needs periodic washing

In industrial air and gas treatment columns (scrubbers), the outgoing gas stream often carries a liquid component in the form of tiny droplets (mist), generated by upstream washing, cooling, or chemical reaction processes.

The demister, also known as a mist eliminator, is the device installed at the top of the column that captures these droplets and returns a clean gas stream before it is released into the atmosphere or sent to the next process stage.

Structurally, a demister is typically built as a mesh pad of woven metal or polymer wire, or as a pack of shaped lamellae (vane pack): in both cases, the operating principle relies on impact and coalescence. Droplets carried by the gas strike the dense mesh of surfaces, merge into larger drops, and fall back down the column under gravity, while the purified gas continues on its way.

Precisely because of its dense mesh structure, the demister is also the point in the plant most exposed to the build-up of solid particulate, scaling, and chemical residue carried by the process flow. If these deposits are not removed regularly, the filtering surface progressively clogs: the pressure drop across the column increases, droplet-separation efficiency decreases, and, in the most critical cases, the gas flow can be partially blocked, halting the entire plant.

For this reason, most industrial demisters are equipped with a dedicated washing system, with nozzles positioned above or alongside the filter pack that periodically spray the surface and maintain its separation capacity over time.

Thanks to our experience in designing industrial atomization systems, we support equipment and plant manufacturers from the earliest design stages, calculating the spray-body layout best suited to ensure thorough, continuous washing of the demister.

The challenge

A customer specializing in the construction of industrial equipment made of composite materials and fiberglass was developing a process column fitted with an internal demister and needed to integrate a washing system.

The customer asked us for engineering support to determine three elements with precision: the number of nozzles required, their layout on the washing plane, and the correct distance from the demister surface. This information was essential both for validating the structural design of the mounting of the component and for correctly sizing the manifolds.

The main constraint was hydraulic: the washing circuit’s supply line was already configured with a DN20 line at an operating pressure of 5 bar — a fixed parameter to which the washing solution had to adapt.

Added to this was the need to assess, based on the coverage that could actually be achieved, whether a standard linear collector configuration would be sufficient or a more complex distribution architecture would be required.

The customer asked us to design the washing system for a demister in a fiberglass scrubber

Our solution

Our technical department analyzed the preliminary layout of the demister housing and developed a coverage study dedicated to this specific case.

To meet the 5-bar pressure constraint and make the best use of the flow available on the DN20 line, we proposed a configuration comprising 7 nozzles from the EBU family, made of AISI 316L stainless steel.
The wide spray angle of these nozzles reduces the distance between the manifold and the demister surface, maximizing the area covered by each jet and thereby reducing the overall number of spray points required.

The study defined a radial positioning pattern with jets calibrated to overlap, thereby eliminating any shadow zone left unreached by the washing action.

COLUMN WITH DEMISTER
WASHING IN ACTION
ISOMETRIC VIEW

WASHING SYSTEM WITH MANIFOLD AND NOZZLES
FRONT VIEW

Key benefits

The precise overlap of the spray cones ensures total, uniform coverage of the demister surface, eliminating the risk of solids build-up and preserving the column’s droplet-separation efficiency over time.

e

FULL CONE NOZZLE

The E-type full cone nozzle works on the impact principle. It deflects a water stream that impacts onto a spiral-profiled surface, providing the desired spray angle.