Can’t find your industry? Contact us!
Our products meet the needs of all industries, from the steel to the food and chemical and pharmaceutical sectors.
A section entirely dedicated to our catalogs, brochures, videos and insights into the world of sprays. Our knowledge at your service.
SPRAY NOZZLES AND ACCESSORIES CATALOG
Download the PNR Italia catalog to explore the complete range of quick-release nozzles and accessories for industrial applications.
Our company offers a range of services to its customers including a laboratory equipped for spraying tests, a dedicated department for CFD simulations, one dedicated to certifications and specific ongoing support for engineering companies, plant engineers and OEMs.
Whether designing, testing, measuring or simulating, PNR Italia ‘s expertise is what you are looking for.
QUALITY AND CERTIFICATIONS
Discover PNR Italia’s company and product certifications.
Home > Casi Studio > How to wash a demister in a fiberglass column
“With a demister, the challenge isn’t washing more; it’s washing well: we studied the nozzle layout jet by jet to guarantee full surface coverage while staying within the flow and pressure limits of the existing line.”
STEFANO BISSACO
Sales Manager
In industrial air and gas treatment columns (scrubbers), the outgoing gas stream often carries a liquid component in the form of tiny droplets (mist), generated by upstream washing, cooling, or chemical reaction processes.
The demister, also known as a mist eliminator, is the device installed at the top of the column that captures these droplets and returns a clean gas stream before it is released into the atmosphere or sent to the next process stage.
Structurally, a demister is typically built as a mesh pad of woven metal or polymer wire, or as a pack of shaped lamellae (vane pack): in both cases, the operating principle relies on impact and coalescence. Droplets carried by the gas strike the dense mesh of surfaces, merge into larger drops, and fall back down the column under gravity, while the purified gas continues on its way.
Precisely because of its dense mesh structure, the demister is also the point in the plant most exposed to the build-up of solid particulate, scaling, and chemical residue carried by the process flow. If these deposits are not removed regularly, the filtering surface progressively clogs: the pressure drop across the column increases, droplet-separation efficiency decreases, and, in the most critical cases, the gas flow can be partially blocked, halting the entire plant.
For this reason, most industrial demisters are equipped with a dedicated washing system, with nozzles positioned above or alongside the filter pack that periodically spray the surface and maintain its separation capacity over time.
Thanks to our experience in designing industrial atomization systems, we support equipment and plant manufacturers from the earliest design stages, calculating the spray-body layout best suited to ensure thorough, continuous washing of the demister.
A customer specializing in the construction of industrial equipment made of composite materials and fiberglass was developing a process column fitted with an internal demister and needed to integrate a washing system.
The customer asked us for engineering support to determine three elements with precision: the number of nozzles required, their layout on the washing plane, and the correct distance from the demister surface. This information was essential both for validating the structural design of the mounting of the component and for correctly sizing the manifolds.
The main constraint was hydraulic: the washing circuit’s supply line was already configured with a DN20 line at an operating pressure of 5 bar — a fixed parameter to which the washing solution had to adapt.
Added to this was the need to assess, based on the coverage that could actually be achieved, whether a standard linear collector configuration would be sufficient or a more complex distribution architecture would be required.
The customer asked us to design the washing system for a demister in a fiberglass scrubber
Our technical department analyzed the preliminary layout of the demister housing and developed a coverage study dedicated to this specific case.
To meet the 5-bar pressure constraint and make the best use of the flow available on the DN20 line, we proposed a configuration comprising 7 nozzles from the EBU family, made of AISI 316L stainless steel.
The wide spray angle of these nozzles reduces the distance between the manifold and the demister surface, maximizing the area covered by each jet and thereby reducing the overall number of spray points required.
The study defined a radial positioning pattern with jets calibrated to overlap, thereby eliminating any shadow zone left unreached by the washing action.
COLUMN WITH DEMISTER
WASHING IN ACTION
ISOMETRIC VIEW
WASHING SYSTEM WITH MANIFOLD AND NOZZLES
FRONT VIEW
The precise overlap of the spray cones ensures total, uniform coverage of the demister surface, eliminating the risk of solids build-up and preserving the column’s droplet-separation efficiency over time.
The E-type full cone nozzle works on the impact principle. It deflects a water stream that impacts onto a spiral-profiled surface, providing the desired spray angle.